Conductor£ºbare,
tinned copper
Insulator: silicone rubber
Rated Volt.£º 600V
Test Voltage: 2000V. 1Min
Rated Temp.£º-60¡æ¡«+200¡æ
Mechanical properties:
Un-aged condition:
Tensile strength: 3.45N/mm2 min.
Elongation at break of insulation: ¡Ý100%
Min.Bending radius: 6¡ÁOD
Standards: Standard: UL758,
UL62, And UL1581
Meet with
RoHS, REACH rules.
Characteristics:
Silicone rubber wire & cable have very good flexibility and
good performance of resistance to high temperature, range from -55¡æ up to 200¡æ.
The use of silicone rubber, a high grade corona resistant
insulation material, gives the cable excellent dielectric strength.
Application:
Silicone wire & cable are used where high flexibility is
required and high temperature conditions. It is therefore a suitable connection
cable for home electric appliance, high voltage machines like transformers,
generators, motors, traction machines.
AWG
|
Conductor
|
Insulation
|
Wire OD
|
Resistance
|
Size
|
Structure
|
OD
|
Normal
|
Normal
|
Tolerance
|
¦¸/KM
|
NO.
|
mm2
|
No./mm
|
mm
|
mm
|
mm
|
mm
|
Max.
|
26
|
0.128
|
7/0.16
|
0.48
|
0.76
|
2.00
|
¡À0.10
|
148
|
24
|
0.205
|
7/0.20
|
0.6
|
0.76
|
2.15
|
¡À0.10
|
93
|
22
|
0.324
|
7/0.25
|
0.75
|
0.76
|
2.3
|
¡À0.15
|
55
|
20
|
0.519
|
7/0.31 10/0.26
|
0.96
|
0.69
|
2.4
|
+0/-0.10
|
34.6
|
18
|
0.823
|
7/0.39 16/0.26
|
1.20
|
0.76
|
2.75
|
¡À0.20
|
21.8
|
16
|
1.31
|
7/0.49
|
1.47
|
0.76
|
3.00
|
¡À0.20
|
13.7
|
26/0.26
|
1.55
|
0.76
|
3.10
|
14
|
2.08
|
7/0.62 41/0.254
|
1.90
|
0.76
|
3.45
|
¡À0.25
|
8.62
|
12
|
3.31
|
19/0.50 43/0.32
|
2.50
|
0.76
|
4.05
|
¡À0.25
|
5.38
|
26
|
0.128
|
1/0.42
|
0.42
|
0.76
|
1.95
|
¡À0.10
|
142
|
24
|
0.205
|
1/0.52
|
0.52
|
0.76
|
2.05
|
¡À0.10
|
89
|
22
|
0.324
|
1/0.65
|
0.65
|
0.76
|
2.20
|
¡À0.15
|
54.3
|
20
|
0.519
|
1/0.82
|
0.82
|
0.76
|
2.35
|
¡À0.15
|
33.9
|
18
|
0.823
|
1/1.05
|
1.05
|
0.76
|
2.60
|
¡À0.20
|
21.4
|
16
|
1.31
|
1/1.30
|
1.30
|
0.76
|
2.85
|
¡À0.20
|
13.5
|
|